Specifications

Troubleshooting 5-41
M M L 0 0
5.2.42. E2EC FOLDING KNIFE POS. ERROR
Figure 5-21. Error Codes E2EB & E2EC
PRIMARY FACTOR;
During of the Folding Knife operation, the Folding Knife HP PS continues being ON (L) or does
not turn on (L).
PHENOMENON CAUSES & CHECK POINTS CORRECTIONS Maintenance
Ref + Page
1. This phenomenon
occurs because
the Folding Knife
does not operate.
1. The drive system for the
Folding Knife is faulty.
Check:
Folding Knife or its environs.
2. The breaking of cables or
the disconnecting of
connectors.
Repair the cable or reset the
connector
CN8 - M19
3. Motor fault. Replace:
Folding Knife Motor (M19)
3.5, 3-7
4. PCB fault. Replace: FS-108H/HBM P/K 3.5, 3-7
2. This phenomenon
occurs though the
Folding Knife
operates.
1. The mounting of the
sensor is faulty.
Reset the Sensor correctly.
Folding Knife HP PS (PS22)
3.4, 3-3
2. Sensor fault. Replace:
Folding Knife HP PS (PS22)
3.4, 3-3
3. The breaking of cables or
the disconnecting of
connectors.
Repair the cable or reset the
connector
CN25 - PS20
4. PCB fault. Replace: FS-108H/HBM P/K
3.5, 3-7