Specifications
5-40 DDP92/184 Finisher Maintenance Manual
M M L 0 0
5.2.41. E2EB FOLDING STOPPER ERROR
PRIMARY FACTOR; During the Folding Stopper operation, the stopper cannot detected.
PHENOMENON CAUSES & CHECK POINTS CORRECTIONS Maintenance
Ref + Page
1. This phenomenon
occurs because
the Folding
Stopper does not
operate.
1. The drive system for the
Folding Stopper is faulty.
Check:
Folding Stopper or its environs.
2. The breaking of cables or
the disconnecting of
connectors.
Repair the cable or reset the
connector
CN9 - M18
3. Motor fault. Replace:
Folding Stopper Motor (M18) 3.5, 3-7
4. PCB fault. Replace: FS-108H/HBM P/K 3.5, 3-7
2. This phenomenon
occurs though the
Folding Stopper
operates.
1. The mounting of the
sensor is faulty.
Reset the Sensor correctly.
Folding Stopper HP PS (PS27)
3.4, 3-3
2. Sensor fault. Replace:
Folding Stopper HP PS (PS27)
3.4, 3-3
3. The breaking of cables or
the disconnecting of
connectors.
Repair the cable or reset the
connector
CN9 - PS27
4. PCB fault. Replace: FS-108H/HBM P/K 3.5, 3-7
Refer to Figure 5-21.