Specifications
Troubleshooting 5-39
M M L 0 0
5.2.40. E2EA STOPPER RELEASE MOTOR ERROR
Figure 5-20. Error Code E2EA
PRIMARY FACTOR; During the Stapling & Folding Stopper operation, the Stopper cannot detected.
PHENOMENON CAUSES & CHECK POINTS CORRECTIONS Maintenance
Ref + Page
1. This phenomenon
occurs because
the Stapling &
Folding Stopper
does not operate.
1. The drive system for the
Stapling & Folding
Stopper is faulty.
Check:
Stapling & Folding Stopper or its
environs.
2. The breaking of cables or
the disconnecting of
connectors.
Repair the cable or reset the
connector
CN26 - M17
3. Motor fault. Replace:
Stapling & Folding Stopper
Release Motor (M17)
3.5, 3-7
4. PCB fault. Replace: FS-108H/HBM P/K 3.5, 3-7
2. This phenomenon
occurs though the
Stapling & Folding
Stopper operates.
1. The mounting of the
sensor is faulty.
Reset the Sensor correctly.
Stapling & Folding Stopper
Release Motor HP PS (PS21)
3.4, 3-3
2. Sensor fault. Replace:
Stapling & Folding Stopper
Release Motor HP PS (PS21)
3.4, 3-3
3. The breaking of cables or
the disconnecting of
connectors.
Repair the cable or reset the
connector
CN26 - PS21
3.5, 3-7
4. PCB fault. Replace: FS-108H/HBM P/K 3.5, 3-7