5-38 DDP92/184 Finisher Maintenance Manual
M M L 0 0
5.2.39. E2E9 ALIGNMENT PLATE/LOWER POS. ERROR
PRIMARY FACTOR; During the Alignment Plate/Lower operation, the plate cannot be detected.
PHENOMENON CAUSES & CHECK POINTS CORRECTIONS Maintenance
Ref + Page
1. This phenomenon
occurs because
the Alignment
Plate/Lower does
not operate.
1. The drive system for the
Alignment Plate/Upper is
faulty.
Check:
Alignment Plate/Lower or its
environs.
2. Motor fault. Replace:
Alignment Plate/Lower Motor
(M15)
3.5, 3-7
3. The breaking of cables or
the disconnecting of
connectors.
Repair the cable or reset the
connector
CN27 - M15
4. PCB fault. Replace: FS-108H/HBM P/K
3.5, 3-7
2. This phenomenon
occurs though the
Alignment
Plate/Lower
operates.
1. The mounting sensor is
faulty.
Reset the Sensor correctly.
Alignment Plate/Lower HP PS
(PS24)
3.4, 3-3
2. Sensor fault. Replace:
Alignment Plate/Lower HP PS
(PS24)
3.4, 3-3
3. The breaking of cables or
the disconnecting of
connectors.
Repair the cable or reset the
connector
CN27 - PS24
4. PCB fault. Replace: FS-108H/HBM P/K
3.5, 3-7
Refer to Figure 5-16.