Specifications

Troubleshooting 5-31
M M L 0 0
5.2.30. E2C5 STAPLER ROTATE ERROR 1
E2CB STAPLER ROTATE ERROR 2
PRIMARY FACTOR; During the Stapler Unit rotation, the Stapler Unit rotation position cannot be detected.
E2C5: slant position, E2CB: parallel position.
PHENOMENON CAUSES & CHECK POINTS CORRECTIONS Maintenance
Ref + Page
1. This phenomenon
occurs because
the Stapler Unit
does not rotate.
1. The drive system for the
Stapler Unit rotation is
faulty.
Check:
Stapler Unit or its environs.
2. Motor fault. Replace: Stapler Rotation
Motor (M4)
3.5, 3-7
3. The breaking of cables or
the disconnecting of
connectors.
Repair the cable or reset the
connector
CN23 - M4
4. PCB fault. Replace: FS-108H/HBM P/K
3.5, 3-7
2. This phenomenon
occurs though the
Stapler Unit
rotate.
1. The mounting of the
sensor is faulty.
Reset the sensor correctly
Stapler Rotation HP PS (PS14)
3.4, 3-3
2. The breaking of cables or
the disconnecting of
connectors.
Repair the cable or reset the
connector
CN24 - PS14
3. Sensor fault. Replace:
Stapler Rotation HP PS (PS14)
3.4, 3-3
4. PCB fault. Replace: FS-108H/HBM P/K 3.5, 3-7
Refer to Figure 5-15.