Power Consumption / Noise Emission
Power Consumption
Model Configuration Power consumption BTU
D129
D130
Main unit only
Under 1580 Watts (max) 5931.2
Full Configuration Under 1584 Watts (max) 5404.8
Noise Emission
Sound
Condition Model Main Unit
Sound Power Level
(Mainframe Only)
Stand-by
D129 Less than 45db
D130 Less than 48db
Copying
D129 Less than 70db
D130 Less than 72db
Sound Power Level
(Full System)
Stand-by
D129 Less than 45db
D130 Less than 48db
Copying
D129 Less than 74db
D130 Less than 76db
Sound Pressure Level
(Mainframe Only)
Stand-by
D129 Less than 39db
D130 Less than 42db
Copying
D129 Less than 64db
D130 Less than 66db
Sound Pressure Level
(Full System)
Stand-by
D129 Less than 39db
D130 Less than 42db
Copying
D129 Less than 68db
D130 Less than 70db
• Sound power level and sound pressure level are actual values measured in accordance with
ISO 7779.
• Sound power level and sound pressure level are measured from the position of the bystander.
• The complete system consists of the main unit, booklet finisher, ADF, bridge unit, internal tray 2,
and paper tray unit.