Specifications

Product Support Guide
D104/D106
Ver.1.5 Page 11 of 43 12/9/2011
Ozone/ Dust / Styrene / TVOC / Benzene Emission Level (Target)
*Please note these are targeted value only. Please refer to “Product Environment Information” for actual data.
Full Color (mg/ h) Monochrome (mg/h)
Ozone Emission Stand by + Copying 3.0 mg/h or less 1.5 mg/h or less
Dust Stand by + Copying 4.0 mg/h or less 4.0 mg/h or less
Styrene Emission Stand by + Copying 1.8 mg/h or less 1.0 mg/h or less
TVOC (*)
Stand by 2.0 mg/h or less 2.0 mg/h or less
Stand by + Copying 18.0 mg/h or less 10.0 mg/h or less
Benzene Stand by + Copying Less than 0.05 mg/h Less than 0.05mg/h
(*) TVOC: Total Volatile Organic Compounds
NOTE: The above measurements were made in accordance with ISO
7779. The measurements were taken from the normal position of
the operator.
Installation Times
Mainframe: 30 minutes
Peripherals:
Peripherals
Installation Time
(Minutes)
Internal Options
Installation Time
(Minutes)
ARDF* 15 PostScript3 5
1-Tray Paper Feed unit 10 PictBridge 5
2-Tray Paper Feed unit 10 IEEE802.11a/g 5
1 bin Tray 10 Gigabit Ethernet 5
Shift Tray 10 IEEE 1284 5
Side Tray 10 File Format Converter 10
Internal Finisher 15 Envelop Feeder 5
Punch Unit 30 Caster Table 5
FAX Option 15 Platen Cover 5
USB/SD Slot 10 Fax Hand Set 5
Storage/Transportation
Storage Transportation
Mainframe
Temperature/humidity
- 30
0
C 40
o
C(86
0
F-104
o
F) Less than 85%RH
Storage Period:
Maximum 12 months from production
Temperature/humidity:
-30
0
C– 45
0
,C (86
o
F-113
o
F)15% - 95%RH
Toner (*1)
Temperature/humidity
50
0
C or less
(Do not leave under 36
0
C~ 40
0
C(96.8
0
F-104
0
F) over
one month or under 50
0
C over 12 hours)
Avoid direct sunlight
15% ~ 80% RH
Storage Period
Storage period: Max 12 months
Other condition is same as storage
NOTE: Do not store more than 12 hours under the temperature between 40 C and 50
0
C(86
0
F-122
0
F). Do not store more than a
month under the temperature between 35
0
C and 40
0
C(95
0
F-104
0
F). Store in a dry, dark place where temperature does
not exceed 40
0
C (104
0
F) on continuance storage/transportation conditions.
0
Subject to change without notice