Service manual

SC TABLE 30 July, 2001
4-16
SC No. Item Definition Possible Cause
Related
SCs
Troubleshooting Procedure Type
SC 460-
001
Thermistor 1
error (open
circuit)
When the temperature
detected by thermistor 1,
which is at the left (fusing unit)
side of the laser optics unit, is
less than -30°C for 10 seconds
consecutively, the BCU
determines that the circuit is
opened and displays this SC
code.
Thermistor 1
defective
Cable connection
error
BCU defect
1. Turn the main switch off and on.
2. Check the cable connections.
3. Replace the thermistor.
4. Replace the BCU.
SC 460-
002
Thermistor 1
error (short
circuit)
When the temperature
detected by the thermistor 1,
which is at the left (fusing unit)
side of the laser optics unit, is
higher than 70°C for 10
seconds consecutively, the
BCU determines that the
circuit is shorted and displays
this SC code
Thermistor 1
defective
Cable connection
error
BCU defect
1. Turn the main switch off and on.
2. Check the cable connections.
3. Replace the thermistor.
4. Replace the BCU.
SC 461-
001
Thermistor 2
error (open
circuit)
When the temperature
detected by the thermistor 2,
which is at the right (paper
feed section) side of the laser
optics unit, is less than -30°C
for 10 seconds consecutively,
the BCU determines that the
circuit is opened and displays
this SC code.
Thermistor 2
defective
Cable connection
error
BCU defect
1. Turn the main switch off and on.
2. Check the cable connections.
3. Replace the thermistor.
4. Replace the BCU.