Service manual

30 July, 2001 SC TABLE
4-13
SC No. Item Definition Possible Cause
Related
SCs
Troubleshooting Procedure Type
SC 285
Line position
adjustment
(MUSIC) error
Line position adjustment fails
three consecutive times.
Pattern sampling
error due to
insufficient image
density of patterns
used for the
adjustment
Inconsistency in the
sampling line position
adjustment pattern
due to dust on the
pattern, damage to
the OPC drum,
damage or toner
dropped on the
transfer belt, or a dirty
or defective ID sensor
1. Turn the main switch off and on.
2. Check and fix the problem that
causes low image density. .
3. Clean or replace the transfer belt
and/or the ID sensor.
4. Replace the PCU or clean the
development unit that causes toner to
drop on the transfer belt.
SC 370 TD sensor [K]:
Adjustment
error
SC 371 TD sensor [Y]:
Adjustment
error
SC 372 TD sensor [C]:
Adjustment
error
SC 373 TD sensor [M]
: Adjustment
error
During the developer
initialization, the output value
of the TD sensor is without the
adjustment range (3.0 ± 0.1V).
Poor connection (TD
sensor outputs is less
than 0.5V.)
Defective TD sensor
1. Turn the main switch off and on.
2. Reset the related color development
unit.
3. Replace the related color
development unit.
SC 374 Vt error [K]
SC 375 Vt error [Y]
SC 376 Vt error [C]
SC 377 Vt error [M]
During the image
development, Vt value is less
than 0.5V.
Poor connection (TD
sensor outputs is less
than 0.5V.)
Defective TD sensor
1. Turn the main switch off and on.
2. Reset the related color development
unit.
3. Replace the related color
development unit.