Service manual

LASER EXPOSURE 30 July, 2001
6-24
Main Scan Skew Adjustment
The 3rd mirror positioning motors [A] for magenta, cyan, and yellow each adjust the
angle of the 3rd mirror [B], based on the 3rd mirror position for black. This corrects
main scan skew.
G060D254.WMF
[A]
[B]