Service manual
30 July, 2001 PRINTER ENGINE SERVICE MODE
5-43
Service
Tables
7
Mode No.
(Class 1, 2, and 3)
Function / [ Setting ]
[Tray Clear] Paper Tray Counter Clear
1Tray 1
2Tray 2
3 Tray 3/LCT
4Tray 4
816
6 Duplex
*
P
Clears the counters (SP7-204) for the number of
sheets fed from the paper feed stations.
NOTE: The LCT is counted as the 3rd feed
station.
[Counter Reset]
825
1 Counter Reset P Rests the total counter values to “0”.
NOTE: This SP mode can be done only once,
while the counter values are less than 0.
[Diag. Result] Diagnostic Result
832
1 Diag. Result *
P
Displays the result of the diagnostics.
[Coverage] Image Coverage Ratio & No. of Toner Cartridges
1 Last [K]
2 Last [C]
3 Last [M]
4 Last [Y]
Displays the image coverage ratio for each color
of the last output.
[ 0 to 100.00 / - / 0.01 %/step ]
5 Average [K]
6 Average [C]
7 Average [M]
8 Average [Y]
Displays accumulated average value of image
coverage ratio for each color.
[ 0 to 100.00 / - / 0.01 %/step ]
11 Toner [K]
12 Toner [C]
13 Toner [M]
833
14 Toner [Y]
*
Displays the total number of toner cartridges
replaced.
[ 0 to 65535 / - / 1 cartridge/step ]
[Asset Info]
1 File Name
2 # of Lines
901
3 Location
P Records the location where a problem is detected
in the program. The data stored in this SP is used
for problem analysis. DFU
[Alert Display]
7 Fusing: Alert * Specifies the timing for displaying the near-end
condition.
With the default setting, near-end is detected and
the alert lights on the panel 2.5K prints before
detecting the end condition. The unit life is 9303K
revolutions.
Increment: Delays the alert display timing.
Decrement: Hastens the alert display timing.
1.0K prints = approximately 93K revolutions
[ 0 to 20000 / 9070 / 1 K revolutions/step ]
905
9 Oil: Alert * Specifies the timing for displaying the near-end
condition.
With the default setting, near-end is detected and
the alert lights on the panel 2.5K prints before
detecting the end condition. The unit life is 1860
revolutions.
Increment: Delays the alert display timing.
Decrement: Hastens the alert display timing.
1.0K prints = 93
[ 0 to 10000 / 1628 / 1 K revolutions/step ]