Service manual
PRINTER ENGINE SERVICE MODE 30 July, 2001
5-30
SP5-XXX (Mode)
5
Mode No.
(Class 1, 2, and 3)
Function / [ Setting ]
[Language]
009
1 Language *
#
P
Selects the language for the control panel.
[ 0 to 16 / 2 / 1/step ]
NOTE: When changing language, the main switch
has to be turned off and on to initialize the
system.
[Counter Method]
045
1 Counter Method *
P
Selects the counting method if the meter charge
mode is enabled with SP5-930-001.
[ 0 or 1 / 0 / - ]
0: Developments
1: Prints
NOTE: The counting method can be changed only
once, regardless of whether the counter
value is negative or positive.
[ROM Update] ROM Update Display
049
1 ROM Update *
P
Enables or disables the ROM Update utility. When
enabled, this utility will be displayed in the user
program mode.
[ 0 or 1 / 1 /- ]
0: Enable
1: Disable
[Energy Saver]
3 Energy Saver 1 *
P
After the end of a job, the machine enters Energy
Saver mode (level 1) when this timer runs out.
[ 0 to 60 / 0 / 10 sec/step ]
101
4 Energy Saver 2
(Auto OFF mode)
*
P
After the end of a job, the machine enters Energy
Saver mode (level 2) when this timer runs out.
[ 0 to 3600 / 3600 / 60 sec/step ]
[Double Count]
104
1 Double Count *
P
Specifies whether the counter is double clicked for
A3/DLT size prints.
[ 0 or 1 / 0 / - ]
0: Normal count
1: Double count
[ES Level 2 Set]
305
1 ES Level 2 Set *
P
Enables or disables Energy Saver Level 2 (Auto
Off mode).
[ 0 or 1 / 0 / - ]
0: Enabled
1: Disabled
Data Language Data language
0
No language
9
Norwegian
1
Japanese
10
Danish
2
English
11
Swedish
3
American
12
Polish
4
French
13
Portuguese
5
German
14
Hungarian
6
Italian
15
Czech
7
Spanish
16
Finnish
8
Dutch