Service manual
30 July, 2001 PRINTER ENGINE SERVICE MODE
5-23
Service
Tables
SP3-XXX (Process)
3
Mode No.
(Class 1, 2, and 3)
Function / [ Setting ]
[TD Initial] TD Sensor Initialization ([Color])
1[K]
2[Y]
3[M]
4[C]
5 [All Color]
Initializes the developer. DFU
Press the Enter key to execute the initialization
after the machine asks “Execute?”.
005
6 Result Displays the developer initialization result.
[ 1 to 9 / - / - ]
1: Success
2 to 9: Failure
All colors are displayed. Values is displayed in the
order K Y C M.
e.g., 1 1 2 1: Initialization of Cyan failed but the
others succeeded
See the troubleshooting section for details.
[Vcnt Initial] Vcnt Initial Setting Display ([Color])
1[K]
2[Y]
3[M]
006
4[C]
Displays the initial Vcnt value.
[ 0 to 240 / 100 / 0.1/step ]
[Vcnt Current] Vcnt Current Value Display ([Color])
1[K]
2[Y]
3[M]
007
4[C]
Displays the current Vcnt value.
[ 0 to 240 / - / 0.1/step ]
[Humidity]
008
1 Humidity Displays the humidity measured by the
humidity/temperature sensor.
[ 0 to 100 / - / 1/step ]
[Vsg Display] Vsg Display (Front or Rear)
1 Vsg F * Displays the Vsg value of the front ID sensor.
[ 0.00 to 5.00 / - / 0.01V/step ]
Vsg is normally 4.0 ± 0.5 V.
If Vsg is out of the adjustment range and this is
detected 3 times consecutively, it leads to SC385.
2 LED Current F * Displays the ID sensor LED current adjusted
during Vsg adjustment.
[ 0 to 1023 / - / 1 ]
3 Vsg R * Displays the Vsg value of the rear ID sensor.
[ 0.00 to 5.00 / - / 0.01V/step ]
Vsg is normally 4.0 ± 0.5 V.
If Vsg is out of the adjustment range and this is
detected 3 times consecutively, it leads to SC385.
107
4 LED Current R * Displays the ID sensor LED current adjusted
during Vsg adjustment.
[ 0 to 1023 / - / 1 ]