Service manual
Service Call Conditions
SM 4-5 M001
Trouble-
shooting
Fusing overheat error – software
543 A
The fusing temperature was detected
higher than 235
o
C for longer than 200
ms.
Fusing thermistor defective
Power supply board defective
High temperature detection: Hard
544 A
The thermister detects a high
temperature signal.
Defective thermister
Defective fusing unit, PSU,
engine board
Fusing lamp remains on
545 A
The fusing lamp remained on longer
than 12 sec. after the fusing unit
reached optimum temperature and the
main motor switched off.
Fusing thermistor defective
Power supply board defective
Defective connection of the
fusing unit
Unstable fusing temperature
During standby, the fusing temperature
went below 60 °C twice or went above
60 °C three times within 500 ms.
546 A
A 60°C increase in fusing temperature
was detected at five 1-sec. intervals
within 60 sec. before reaching fusing
temperature.
Fusing thermistor defective
Power supply board defective
Defective connection of the
fusing unit
CÓPIA NÃO CONTROLADA
CÓPIA NÃO CONTROLADA