4.1.2 SC CODE DESCRIPTIONS
FGATE error
230 B
The PFGATE ON signal does not
assert within 1 second.
The PFGATE ON signal still assert
within 7 seconds, after processing the
image in a normal job
Defective engine board
Defective controller board
Disconnect harness
Charge roller current leak
302 B
The PWM duty output exceeded 60%
for longer than 200 ms, indicating a
leak in the charge roller current.
Cartridge (charge roller)
defective
High voltage supply board
defective
Defective cartridge connection
Polygon motor error
320 B
The polygon motor did not enter the
lock state within 10 sec. after it
switched on.
-or-
Once the polygon motor was detected
in the lock state after started to rotate,
within 0.2 sec. it entered the unlock
state.
-or-
After the polygon motor switched off, it
did not enter unlock state within 3 sec.
Polygon motor
Polygon motor cable
CÓPIA NÃO CONTROLADA