Printer Engine Service Mode
M001 5-34 SM
Confirm Result
5816 204
Displays a number that indicates the result of the inquiry executed with
SP5816 203.
0: Succeeded
1: Inquiry number error
2: Registration in progress
3: Proxy error (proxy enabled)
4: Proxy error (proxy disabled)
5: Proxy error (Illegal user name or password)
6: Communication error
7: Certification update error
8: Other error
9: Inquiry executing
Confirm Place
5816 205
Displays the result of the notification sent to the device from the GW URL in
answer to the inquiry request. Displayed only when the result is registered
at the GW URL.
5816 206 Register Execute Executes Embedded RCG Registration.
Register Result
5816 207
Displays a number that indicates the registration result.
0: Succeeded
2: Registration in progress
3: Proxy error (proxy enabled)
4: Proxy error (proxy disabled)
5: Proxy error (Illegal user name or password)
6: Communication error
7: Certification update error
8: Other error
9: Registration executing
CÓPIA NÃO CONTROLADA