Service manual

Printer Engine Service Mode
M001 5-18 SM
Example: 00:00 (Midnight) = 00, 01:00 (1 a.m.) = 01, and so on.
7th The number of hours to change the time. 1 hour: 1
8th
If the time change is not a whole number (1.5 hours for example),
digit 8 should be 3 (30 minutes).
001 Setting
Enables/disables the settings for 002 and
003.
[0 to 1/1]
0: Disable
1: Enable
003 Rule Set (Start) The start of summer time.
004 Rule Set (End) The end of summer time.
UCodeCtrClr User Code Count Clear
5404
Clears the counts for the user codes assigned by the key operator to restrict
the use of the machine. Press [#Enter] to clear.
PM Alarm
5501
[0 to 9999/0/1 step]
0: Alarm off
1 to 9999: Alarm goes off when Value (1 to 9999) PM counter
Jam Alarm
5504
Sets the alarm to sound for the specified jam level (document misfeeds are
not included).
[0 to 3/3/1 step]
0: Zero (Off)
1: Low (2.5K jams)
2: Medium (3K jams)
3: High (6K jams)