Installation Requirements
Temperature Range:
10 C to 32 C (50 F to 89.6 F)
Humidity Range:
15% to 80% RH
Ambient Illumination:
Less than 1,500 lux (do not expose to direct sunlight)
Ventilation:
3 times/hr/person
Ambient Dust:
Less than 0.075 mg/m
3
(2.0 x 10-6oz/yd
3
)
Avoid areas exposed to sudden temperature changes:
Areas directly exposed to cool air from an air conditioner.
Areas directly exposed to heat from a heater.
Do not place machine where it will be exposed to corrosive gas or vapor.
Do not install the machine at any location over 2,500m (8,200 ft.) above sea level.
Place the machine on a strong and level base. Inclination on any side should be no more than 5mm (0.2”)
Do not place the machine where it may be subject to strong vibrations.
Machine level
Front to back: within 5mm (0.2”) of level
Right to left: within 5mm (0.2”) of level
Power Requirements
Input voltage level: 110 - 120 V, 60Hz: 12A
Do not place anything on power cord.
The required wall outlet is a NEMA 5-15R (receptacle)
Space
Foot Print
A (Left)
Over 100 mm (3.9")
B (Rear)
Over 100 mm (3.9")
C (Right)
Over 550 mm (21.7")
D (Front)
Over 750 mm (29.5")
Dimensions (W x D x H): 22.8 x 28.98 x 41.9 (with 2-Tray Paper Bank and fall-prevention
material) Measurement Conditions: With bypass feed table closed
The recommended 750 mm (30”) front space is sufficient to
allow the paper tray to be pulled out. Additional the front
space is required to allow operators to stand at the front of
the machine.