Service manual

Bit Switches
D127/D128 5-38 SM Appendix
1
Acceptable total error line ratio
0: 5% 1: 10%
If the error line ratio for a page exceeds the
acceptable ratio, RTN will be sent to the other end.
2
Treatment of pages received
with errors during G3
reception
0: Deleted from memory
without printing
1: Printed
0: Pages received with errors are not printed.
3
Hang-up decision when a
negative code (RTN or PIN) is
received during G3 immediate
transmission
0: No hang-up, 1: Hang-up
0: The next page will be sent even if RTN or PIN is
received.
1: The machine will send DCN and hang up if it
receives RTN or PIN.
This bit is ignored for memory transmissions or if
ECM is being used.
4-7 Not used Do not change the settings.
Communication Switch 03 [SP No. 1-104-004]
No FUNCTION COMMENTS
0-7
Maximum number of page
retransmissions in a G3
memory transmission
00 - FF (Hex) times.
This setting is not used if ECM is switched on.
Default setting - 03(H)
Communication Switch 04 [SP No. 1-104-005]
No FUNCTION COMMENTS
0
Remote switch setting for TEL
mode
0: OFF 1: ON
Determines whether remote switching is ON/OFF
on receiving fax transmission, in TEL mode.
1
Remote switch setting for FAX
mode
0: OFF 1: ON
Determines whether remote switching is ON/OFF
on auto receiving, in FAX mode.