Service manual
Bit Switches
SM Appendix 5-25 D127/D128
Appendix:
Fax Trouble-
Shooting
Guide
I-fax Switch 03 - Not used (do not change the settings) [ SP No. 1-102-004]
I-fax Switch 04 [SP No. 1-102-005]
No FUNCTION COMMENTS
0
Subject for Delivery TX/Memory Transfer
This setting determines whether the RTI/CSI registered on this machine or the
RTI/CSI of the originator is used in the subject lines of transferred documents.
0: Puts the RTI/CSI of the originator in the Subject line. If this is used, either the RTI
or CSI is used. Only one of these can be received for use in the subject line.
1: Puts the RTI/CSI registered on this machine in the Subject line.
When this switch is used to transfer and deliver mail to a PC, the information in the
Subject line that indicates where the transmission originated can be used to
determine automatically the destination folder for each e-mail.
1
Subject corresponding to mail post database
0: Standard subject
1: Mail post database subject
The standard subject is replaced by the mail post database subject in the following
three cases:
1) When the service technician sets the service (software) switch.
2) When memory sending, delivery specified by F code or SMTP reception is done.
3) With relay broadcasting (1st stage without the Schmidt 4 function).
This switch does not apply for condition 3) when the RX system is set up
for memory sending, delivery by F-code, sending with SMTP RX and when
operators are using FOL (to prevent problems when receiving
transmissions).