Bit Switches
SM Appendix 5-19 D127/D128
Appendix:
Fax Trouble-
Shooting
Guide
System Switch 1D [SP No. 1-101-030]
No FUNCTION COMMENTS
0
RTI/CSI/CPS code display
0: Enable
1: Disable
0: RTI, CSI, CPS codes are displayed on the top
line of the LCD panel during communication.
1: Codes are switched off (no display)
1-7 Not used Do not change these settings.
System Switch 1E [SP No. 1-101-031]
No FUNCTION COMMENTS
0
Communication after the
Journal data storage area has
become full
0: Impossible
1: Possible
0: When this switch is on and the journal history
becomes full, the next report prints. If the journal
history is not deleted, the next transmission cannot
be received. This prevents overwriting
communication records before the machine can
print them.
1: If the buffer memory of the communication
records for the Journal is full, fax communications
are still possible. But the machine will overwrite
the oldest communication records.
Note: This setting is effective only when Automatic
Journal printout is enabled but the machine cannot
print the report (e.g., no paper).
1
Action when the SAF memory
has become full during
scanning
0: The current page is erased.
1: The entire file is erased.
0: If the SAF memory becomes full during
scanning, the successfully scanned pages are
transmitted.
1: If the SAF memory becomes full during
scanning, the file is erased and no pages are
transmitted.
This bit switch is ignored for parallel memory
transmission.
2
RTI/CSI display priority
0: RTI 1: CSI
This bit determines which identifier, RTI or CSI, is
displayed on the LCD while the machine is
communicating in G3 non-standard mode.