Service manual
Bit Switches
SM Appendix 5-11 D127/D128
Appendix:
Fax Trouble-
Shooting
Guide
System Switch 03 [SP No. 1-101-004]
No FUNCTION COMMENTS
0-7
Length of time that RDS is
temporarily switched on when
bits 6 and 7 of System Switch
02 are set to “User selectable”
00 - 99 hours (BCD).
This setting is only valid if bits 6 and 7 of System
Switch 02 are set to “User selectable”.
The default setting is 24 hours.
System Switch 04 [SP No. 1-101-005]
No FUNCTION COMMENTS
0-2 Not used Do not change these settings.
3
Printing dedicated tx
parameters on Quick/Speed
Dial Lists
0: Disabled
1: Enabled
1: Each Quick/Speed dial number on the list is
printed with the dedicated tx parameters (10 bytes
each).
The first 10 bytes of data are the programmed
dedicated tx parameters; 34 bytes of data are
printed (the other 24 bytes have no use for service
technicians).
4-7 Not used Do not change these settings.
System Switch 05 - Not used (Do not change the factory settings.)
System Switch 06 - Not used (Do not change the factory settings.)
System Switch 07 - Not used (Do not change the factory settings.)