Service manual
System Service Mode
D127/D128 3-144 SM Appendix
021 Added Time: S21 [0 to 999 / 15 / 1 sec/step ]
022 Added Time: S22 [0 to 999 / 15 / 1 sec/step ]
023 Added Time: S23 [0 to 999 / 10 / 1 sec/step ]
024 Added Time: S24 [0 to 999 / 15 / 1 sec/step ]
9915 Fuser Reload Setting [0 to 1 / 0 / 1 sheet/step ]
001
0: Normal / 1: Force Time
Sets the way of fusing reload.
9930 Toner control NV Data [0 to 65535 / 0 / 1 sheet/step ]
008
This SP’s count is used as the flag of toner bottle replacement notice.
When the value becomes more than 1000, the notice will occur and the
value will be cleared.
9946 Fusing Jam Exist [0 to 1 / 0 / 1/step ]
001
0: Not fusing jam existing / 1: Fusing jam existing
This SP tells whether a fusing jam exists or not.
9947 Fuser SC
001 Number [0 to 999 / 0 / 1/step ]
002 Detail [0 to 99 / 0 / 1/step ]