Service manual

System Service Mode
D127/D128 3-74 SM Appendix
100
Notify UnSupport [0: Disabled / 1: Enabled]
Sets banner message popup Enabled/Disabled on unsupported USB device
connection.
5845
Delivery Server Setting CTL -
Provides items for delivery server settings.
001
FTP Port No. [ 0 to 65535 / 3670 / 1 /step]
Sets the FTP port number used when image files to the Scan Router Server.
006
Delivery Error Display Time [0 to 999 / 300 / 1 second /step]
Use this setting to determine the length of time the prompt message is
displayed when a test error occurs during document transfer with the NetFile
application and an external device.
008
Server IP (Secondary)
Range: 000.000.000.000 to
255.255.255.255
Specifies the IP address assigned to the computer designated to function as
the secondary delivery server of Scan Router. This SP allows only the setting
of the IP address without reference to the DNS setting.
009
Delivery Server Model [0 to 4 / 0 / 1 /step]
Allows changing the model of the delivery server registered by the I/O device.
0: Unknown, 1: SG1 Provided, 2: SG1 Package,
3: SG2 Provided, 4: SG2 Package