Service manual
System Service Mode
SM Appendix 3-73 D127/D128
Appendix:
SP Mode
Tables
5844 USB
001
Transfer Rate CTL
Sets the speed for USB data transmission.
[Full Speed]
[Auto Change]
002
Vendor ID CTL
Sets the vendor ID:
Initial Setting: 0x05A Ricoh Company
[0x0000 to 0xFFFF/1] DFU
003
Product ID CTL
Sets the product ID.
[0x0000 to 0xFFFF/1] DFU
004
Device Release Number CTL
Sets the device release number of the BCD (binary coded decimal) display.
[0000 to 9999/1] DFU
Enter as a decimal number. NCS converts the number to hexadecimal number
recognized as the BCD.
005
Fixed USB Port [0 to 3/ 0 / 1 /step ]
Sets the control function saving driver re-install ON/OFF.
0: OFF
1: ON (Level 1)= ON for the same model.
2: ON (Level 2)= Depending on “SP5844 -006,-007”
006
PnP Model Name [20 letter(s)]
Sets the model name for USB PnP when “SP5844-005” is “2”.
007
PnP Serial Number [12 digit]
Sets the serial number for USB PnP when “SP5844-005” is “2”.