Service manual

System Service Mode
SM Appendix 3-17 D127/D128
Appendix:
SP Mode
Tables
2301 12
Plain: 2side: Trail Edge
2301 13
Middle: 1side: Image Area
2301 14
Middle: 1side: Lead Edge
2301 15
Middle: 1side: Trail Edge
2301 16
Middle: 2side: Image Area
2301 17
Middle: 2side: Lead Edge
2301 18
Middle: 2side: Trail Edge
2301 19
Thick: 1side: Image Area
2301 20
Thick: 1side: Lead Edge
2301 21
Thick: 1side: Trail Edge
2301 22
Input: 1side
[0 to 30 / 0 / 1
A/step]
2301 23
Input: 2side
2301 25
Temp Inside the Machine
[-25 to 55 / 20 / 1
A/step]
This temp affects transfer current value.
2301 26
Non Image Area: LL
[0 to 30 / 10 / 1
A/step]
Output current under low temperature condition.
*Refer to SP1105-015 about the condition judge.
2301 27
Non Image Area: MM
[0 to 30 / 13 / 1
A/step]
Output current under normal temperature condition.
*Refer to SP1105-015 about the condition judge.
2301 28
Non Image Area: HH
[0 to 30 / 15 / 1
A/step]
Output current under high temperature condition.
*Refer to SP1105-015 about the condition judge.