Service manual

System Service Mode
SM Appendix 3-5 D127/D128
Appendix:
SP Mode
Tables
1124 CPM Down Setting
1124 1
Low: Down Temp [-50 to 0 / -25 / 1 °C/step]
Sets the temperature for the trigger of CPM down.
1124 2
Low: Up Temp [-50 to 0 / -5 / 1 °C/step]
Sets the temperature for the trigger of CPM up.
1124 3
Low: 1st CPM [10 to 100 / 80 / 1 %/step]
Sets the rate for CPM down. (Low Temp.)
1124 4
Low: 2nd CPM [10 to 100 / 60 / 1 %/step]
The same function as -003, -005
1124 5
Low: 3rd CPM [10 to 100 / 40 / 1 %/step]
The same function as -003, -004
1124 6
High: 1st CPM [10 to 100 / 65 / 1 %/step]
Sets the rate for CPM down. (High Temp.)
1124 7
High: 2nd CPM [10 to 100 / 50 / 1 %/step]
The same function as -006, -008
1124 8
High: 3rd CPM [10 to 100 / 50 / 1 %/step]
The same function as -006, -007
1124 9
High: 1st CPM Down Time.: LT
[0 to 999 / 0 / 1 sec/step]
After motor driving start, CPM (High
temp.) gets one step down in SP’s
value sec later for each paper size.
(SP-9 to -23)
1124 10
High: 2nd CPM Down Time.: LT
1124 11
High: 3rd CPM Down Time.: LT
1124 12
High: 1st CPM Down Time.: A4
1124 13
High: 2nd CPM Down Time.: A4
1124 14
High: 3rd CPM Down Time.: A4
1124 15
High: 1st CPM Down Time.: B5 [0 to 999 / 120 / 1 sec/step]