Service manual

System Service Mode
D127/D128 3-4 SM Appendix
1105 28 Waiting: Center Minus: M - Thick [0 to 60 / 10 / 1 °C/step]
The same function as SP1105 (-024,
-26)
1105 30 Waiting: Center Minus: Thick
1105 32 Waiting: Center Upper: Plain1
[0 to 60 / 40 / 1 °C/step]
Additional value to each paper type
setting temp.. The sum at which or less,
registration waiting starts.
1105 34 Waiting: Center Upper: Plain2
1105 36 Waiting: Center Upper: M - Thick
1105 38 Waiting Center Upper: Thick
1106 Fusing Temperature Display
1106 1
Roller Center [-20 to 250 / 0 / 1 °C/step]
1106 3
In The Machine at Power On [-20 to 250 / 0 / 1 °C/step]
Displays the thermistor temp. at power on.
1108* Control Period Setting
1108 1
Warming-up [100 to 2000 / 100 / 100 msec/step]
1108 2
Print [100 to 2000 / 1000 / 100 msec/step]
1108 3
Wait [100 to 2000 / 1000 / 100 msec/step]
1108 4
Print Start [100 to 2000 / 200 / 100 msec/step]
1108 5
Print Start Time [0 to 999 / 5 / 1 sec/step]
1112 Image Process Temp. Correction
1112 1
Temp.: Normal: Level1
[-25 to 10 / 0 / 1 °C/step]
Sets the additional temperature
1112 2
Temp.: Normal: Level2