Service manual

System Service Mode
D127/D128 3-2 SM Appendix
1103* Fusing Idling
1103 1
Fusing Idling [0 = No / 1 = Yes]
Enables or disables the contact-release control.
1103 2
Reload Temp: Center [90 to 140 / 120 / 1 °C/step]
Sets the degree at which or less reload becomes ON.
1103 3
Threshold [60 to 160 / 100 / 1 °C/step]
Sets threshold-degree for switching forced reload to temperature-judging
reload.
1105*
Fusing Temperature Adjustment
Adjusts the target fusing temperature. Note that the thermistor is at the center
of the hot roller.
1105 1 Roller Center: Plain1
[120 to 200 / 140 / 1 °C/step]
1105 3 Roller Center: Plain2
1105 5 Roller Center: M - Thick [120 to 200 / 145 / 1 °C/step]
1105 7
Thick Paper Roller Center [0 to 40 / 10 / 1 °C/step]
Sets the additional temperature to SP1105-001’s degree for thick paper print.
(i.e.: SP1105-001= 140, This SP= 10, 140+10= 150 degree)
1105 9
Center Minus: Thin [0 to 20 / 5 / 1 °C/step]
Sets the subtractive temperature to SP1105-001’s degree for thin paper print.
(i.e.: SP1105-001= 140, This SP= 5, 140-5= 135 degree)
1105 11
Energy Saver [0 to 80 / 60 / 1 °C/step]
Sets the fusing temperature on energy saving mode.
1105 12 Wait Temp: Center [140 to 160 / 150 / 1 °C/step]
1105 13 Print Ready [140 to 180 / 160 / 1 °C/step]