Service manual

SC Tables
D127/D128 6-28 SM
No.
Definition
Symptom Possible Cause/Countermeasure
839 USB NAND Flash ROM error
839
B
Serial Flash access error
[9001]
The result of reading and writing
in software status register of
Serial Flash, the device for
certification, came to an error.
Defective Serial Flash
[9101]
B
The ID of the USB NAND Flash
ROM cannot be read.
Defective controller board
1. Replace the controller board.
[9110]
B
The USB NAND Flash ROM is
disconnected.
840 B
EEPROM access error
While I/O operation to EEPROM
Three times retry is ineffective
after reading error
Writing error occurs.
Defective EEPROM
841 B
EEPROM reading error
All of the data values being read
from three areas which are given
EEPROM mirroring, are different
from each other.
Particular area in EEPROM has
been changed by some cause
842 D
Nand-Flash update VerifyError
SCS detected abnormal writing
(verifying Error) in the module
which is written in Nand-Flash on
the time of ROM remote update
or ROM update.
Defective Nand-Flash