Service manual
SC Tables
SM 6-27 D127/D128
Trouble –
shooting
No.
Definition
Symptom Possible Cause/Countermeasure
835 Self-diagnostic error: Centronic device
[1102]
C
Loopback connector is
connected but check results in an
error.
IEEE1284 connector error
Centronic loopback connector
defective
1. Replace the controller board.
[110C]
C
Loopback connector is
connected but check results in an
error.
ASIC device error
IEEE1284 connector error
Centronic loopback connector
defective
1. Replace the controller board.
[1120]
C
Centronic loopback connector is
not connected for detailed
self-diagnostic test.
Centronic loopback connector
not connected correctly
Centronic loopback connector
defective
ASIC device defective
1. Replace the controller board.
838
[2701]
B
Self-diagnostic Error: Clock Generator
A verify error occurred when
setting data was read from the
clock generator via the I2C bus.
Defective clock generator
Defective I2C bus
Defective I2C port on the CPU
1. Replace the controller board.