D127/D128 6-22 SM
No.
Definition
Symptom Possible Cause/Countermeasure
B
[0612]: Detailed error code
Cut-in in ASIC occurs.
Defective ASIC
Defective devices in which ASIC
detects cut-in.
1. Replace the controller board.
B
[06FF]: Detailed error code
The pipeline clock frequency
rate is different from the
prescribed value.
Defective CPU devices
Mode bit data error, which is used
for initializing CPU.
1. Replace the controller board.
B
[0702]: Detailed error code
The result when the program is
executed in the command cache
is different from desirable value.
Insufficient CPU cache
Insufficient memory process
speed
1. Replace the controller board.
2. Replace the RAM DIMM.
B
[0709, 070A]: Detailed error code
Even you write the data in the
only cache of memory, the data
is actually written in another
area (not cache) of memory.
Defective CPU devices
Incorrect SPD
Boot mode setting error
1. Replace the controller board.
2. Replace the RAM DIMM.
B
[0801, 0804, 0807, 0808, 0809, 80A]: Detailed error code
An error occurs when checking
the TLB.
Defective CPU devices
1. Replace the controller board.