Service manual

SC Tables
D127/D128 6-10 SM
No.
Definition
Symptom Possible Cause
490 B
Toner bottle motor overcurrent
Detecting "Low" for more than
200msec while the motor on.
Motor locked up due to overcurrent
to the drive section.
Defective the motor drive.
500 B
Main motor error
DetectingHigh” condition twenty
times in series during watching
each lock signal after switching
motor on.
Overload
Defective main motor drive
541 A
Fusing thermistor disconnection
Detecting the temperature remains
lower than 0 degrees Celsius for 5
seconds.
Thermistor disconnection
Defective connector part
542 Fusing reload failed
-001 A
Fusing temperature warm-up error
The fusing temperature doesn’t
rise by more than 7 degrees for
two seconds; and this happens
5 times consecutively.
The measure is start in 3.5 seconds
after activation of the heater.
This monitoring will stop in the case
of reaching the reload temperature.
Defective thermistor
Power source is out of warranty