Service manual

SC Tables
D127/D128 6-8 SM
No.
Definition
Symptom Possible Cause
391 B
Development bias error
The maximum rate of PWM duty
(50%) occurs 10 times in series
(20msec x 10)
This error doesn’t happen when the
front door (the inter lock) opens.
Defective the MD
Defective harness connected to
the HVP
392 B
Developer initialization error
The P sensor does not detect a
correct pattern during developer
initialization (SP2-801-001).
When Vsp output is more than
2.5V, SC appears in the case of not
removing the heat seal or an
absence of developer.
Defective P sensor
Defective T sensor
NOT removing heat-seal
Defective drum operation
Defective development roller
operation
401 B
Transfer roller leak error (positive electrode)
The feedback voltage of the
transfer roller has been more
than the certain voltage for
200msec. (Open detecting
condition)
The feedback voltage of the
transfer roller has been
insufficient for 200msec. (Leak
detecting condition)
This error doesn’t happen when the
front door (the inter lock) opens.
Defective harness connected to
HVP
Defective the MD