Service manual
ENGINE SERVICE MODE
SM 5-33 G130/G131
Service Tables
2801
[PA Roller Cur.] Paper Attraction Roller Current
([Color], Simplex or Duplex/Rear, Process Speed): Current Adjustment
(Paper or By-pass): Paper Size Correction
Paper Type -> TH: Thick Paper, MT: Middle Thick Paper, SP: Special Paper, OHP
Adjusts the paper attraction roller current for color printing.
If paper misfeeds occur at the transfer unit in color mode, check and/or adjust the
paper attraction roller current.
NOTE: The magenta development section is close to the paper attraction roller.
Decreasing the current may not cause paper misfeed.
If the current is increased too much, the following image problems may occur
depending on the humidity.
High humidity:
Insufficient image transfer in magenta due to current flow to the magenta OPC drum
Low humidity:
Offset image in magenta halftone areas due to paper charged positive too much
When adjusting the current with this SP mode, the value should be lower than
transfer current.
2801 001 [K] N S L *BCU
[0 to 50 / 4
/ 1 µA/step]
2801 002 [K] N S M *BCU
[0 to 50 / 8
/ 1 µA/step] Only for G131
2801 003 [K] N S H *BCU
[0 to 50 / 8
/ 1 µA/step] Only for G130
2801 004 [K] N R L *BCU
[0 to 50 / 4
/ 1 µA/step]
2801 005 [K] N R M *BCU
[0 to 50 / 8
/ 1 µA/step] Only for G131
2801 006 [K] N R H *BCU
[0 to 50 / 8
/ 1 µA/step] Only for G130
2801 008 [FC] N S L *BCU
[0 to 50 / 1
/ 1 µA/step]
2801 009 [FC] N S M *BCU
[0 to 50 / 1
/ 1 µA/step]
2801 010 [FC] N R L *BCU
[0 to 50 / 5
/ 1 µA/step]
2801 011 [FC] N R M *BCU
[0 to 50 / 10
/ 1 µA/step]
2801 013 [K] B TH S *BCU
[0 to 50 / 5
/ 1 µA/step]
2801 014 [FC] B TH S *BCU [10 to 50 / 1 / 0.1/step]
2801 015 [K] B OHP *BCU [10 to 50 / 5 / 0.1/step]
2801 016 [FC] B OHP *BCU [10 to 50 / 1 / 0.1/step]
2801 017 [K] B TH D *BCU [10 to 50 / 5 / 0.1/step]
2801 018 [FC] B TH D *BCU [10 to 50 / 1 / 0.1/step]
2801 020 [K] SP S: L *BCU [10 to 50 / 4 / 0.1/step]
2801 021 [K] SP S: M *BCU [10 to 50 / 8 / 0.1/step] Only for G131
2801 022 [K] SP S: H *BCU [10 to 50 / 8/ 0.1/step] Only for G130
2801 023 [K] SP R: L *BCU [10 to 50 / 4 / 0.1/step]
2801 024 [K] SP R: M *BCU [10 to 50 / 8 / 0.1/step] Only for G131
2801 025 [K] SP R: H *BCU [10 to 50 / 8 / 0.1/step] Only for G130
2801 026 [FC] SP S L *BCU
[0 to 50 / 1
/ 1 µA/step]
2801 027 [FC] SP S M *BCU
[0 to 50 / 1
/ 1 µA/step]
2801 028 [FC] SP R L *BCU
[0 to 50 / 5
/ 1 µA/step]
2801 029 [FC] SP R M *BCU
[0 to 50 / G130: 8
, G131: 10 / 1 µA/step]
2801 031 [K] MT L *BCU
[0 to 50 / 4
/ 1 µA/step]
2801 032 [K] MT M *BCU
[0 to 50 / 8
/ 1 µA/step] Only for G131
2801 033 [K] MT H *BCU
[0 to 50 / 8
/ 1 µA/step] Only for G130
2801 034 [K] MT D L *BCU
[0 to 50 / 4
/ 1 µA/step]
2801 035 [K] MT D M *BCU
[0 to 50 / 8
/ 1 µA/step] Only for G131
2801 036 [K] MT D H *BCU
[0 to 50 / 8
/ 1 µA/step] Only for G130
2801 038 [FC] MT L *BCU
[0 to 50 / 1
/ 1 µA/step]
2801 039 [FC] MT M *BCU
[0 to 50 / 1
/ 1 µA/step]
2801 040 [FC] MT D L *BCU
[0 to 50 / 5
/ 1 µA/step]
2801 041 [FC] MT D M *BCU
[0 to 50 / G130: 8
, G131: 10 / 1 µA/step]
2801 042 [K] SP2 L *BCU
[0 to 50 / 4
/ 1 µA/step]
2801 043 [K] SP2 D L *BCU
[0 to 50 / 4
/ 1 µA/step]