PROCESS CONTROL ERROR CONDITIONS
SM 4-5 G130/G131
Trouble-
shooting
No. Result Description Note
29
Yellow skew
correction error
The detected skew correction value is out of the
adjustment range (yellow only).
36
Cyan magnification
error
The detected magnification value is out of the
adjustment range (cyan only).
37
Cyan sub scan
registration error
The detected sub scan registration is out of the
adjustment range (cyan only).
38
Cyan main scan
registration error
The detected main scan registration is out of the
adjustment range (cyan only).
39
Cyan skew
correction error
The detected skew correction value is out of the
adjustment range (cyan only).
46
Yellow & cyan
magnification error
The detected magnification value is out of the
adjustment range (yellow + cyan).
47
Yellow & cyan sub
scan registration
error
The detected sub scan registration is out of the
adjustment range (yellow + cyan).
48
Yellow & cyan
main scan
registration error
The detected main scan registration is out of the
adjustment range (yellow + cyan).
49
Yellow & cyan
skew correction
error
The detected skew correction value is out of the
adjustment range (yellow + cyan).
56
Magenta
magnification error
The detected magnification value is out of the
adjustment range (magenta only).
57
Magenta sub scan
registration error
The detected sub scan registration is out of the
adjustment range (magenta only).
58
Magenta main
scan registration
error
The detected main scan registration is out of the
adjustment range (magenta only).
59
Magenta skew
correction error
The detected skew correction value is out of the
adjustment range (magenta only).
66
Yellow & magenta
magnification error
The detected magnification value is out of the
adjustment range (yellow + magenta).
67
Yellow & magenta
sub scan
registration error
The detected sub scan registration is out of the
adjustment range (yellow + magenta).
68
Yellow & magenta
main scan
registration error
The detected main scan registration is out of the
adjustment range (yellow + magenta).
69
Yellow & magenta
skew correction
error
The detected skew correction value is out of the
adjustment range (yellow + magenta).
76
Cyan & magenta
magnification error
The detected magnification value is out of the
adjustment range (cyan + magenta).
77
Cyan & magenta
sub scan
registration error
The detected sub scan registration is out of the
adjustment range (cyan + magenta).
78
Cyan & magenta
main scan
registration error
The detected main scan registration is out of the
adjustment range (cyan + magenta).
79
Cyan & magenta
skew correction
error
The detected skew correction value is out of the
adjustment range (cyan + magenta).