Service manual
TRANSFER AND PAPER TRANSPORT UNIT
SM 3-31 G130/G312
Replacement
and
Adjustment
3.9.2 TRANSFER BELT CLEANING UNIT
NOTE: Reset the maintenance counter, (SP7-804-18) after you replace the
transfer belt-cleaning unit.
Pull out the transfer belt-cleaning unit [A] ( x 1) at the same time you push the
lever.
NOTE:
1) The blade [B] can damage the belt if you do not continue to push the
lever.
2) Make sure that the transfer unit release lever is put back to the original
position ( 3.7) when you reassemble.
Do a forced line position adjustment (SP5-993-002 or Menu > Maintenance > Color
Regist. > Auto Adjust) after you replace the transfer belt-cleaning unit.
1
2
G130R586.WMFF
[A]
[B]