Service manual

FUSING
SM 6-65 G130/G131
Detailed
Descriptions
6.8.3 FUSING TEMPERATURE CONTROL
Fusing Temperatures
When the main switch turns on, the CPU turns on the fusing lamp. The lamp stays
on until the thermistor detects the standby temperature. Then the CPU raises the
temperature to the printing temperature.
The fusing temperature for each mode is as follows.
Mode
Resolution
(dpi)
Temperature of
Heating Roller
Temperature of
Pressure Roller
Note
Energy saver
level 1
30°C
G130: 105°C
G131: 110°C
Standby mode
175°C 150°C
NOTE: 1)
1,200 x 1,200
135°C 130°C
Color
(simplex/duplex)
1,200 x 600
600 x 600
G130: 140°C
G131: 160°C
G130: 130°C
G131: 145°C
1,200 x 1,200
135°C 130°C
Black and white
(simplex/duplex)
1,200 x 600
600 x 600
160°C 145°C
1,200 x 1,200
140°C 135°C
Middle thick color
(simplex/duplex)
1,200 x 600
600 x 600
G130: 155°C
G131: 175°C
G130: 140°C
G131: 150°C
1,200 x 1,200
140°C 135°C
Middle thick black
and white
(simplex/duplex)
1,200 x 600
600 x 600
175°C 150°C
OHP All
145°C 130°C
Thick All
155 °C 150 °C
NOTE:
1) These are temperatures for standby mode when SP1-104-025 is set to
the default setting. In addition, customers can adjust the temperatures
for standby mode with UP mode.
The heating and pressure roller temperatures for fusing are stored in SP1-105-4 to
-129.
When the machine is switched on, the fusing lamp temperatures increase to those
specified by SP1-104-25.
The print ready temperature is slightly less than the fusing temperature. The
difference is specified by SP1-105-1 and -2.