Service manual

PROCESS CONTROL
G130/G131 6-10 SM
6.2.3 PROCESS CONTROL SELF CHECK PROCEDURE
Step 1: VSG Adjustment
This machine uses three ID sensors (direct reflection type). They are located at the
front, center, and rear of the transfer unit. Only the center ID sensor is used for
process control. The ID sensor checks the bare transfer belt’s reflectivity. Then the
machine calibrates the ID sensor until its output (known as VSG) is as follows.
VSG = 4.0 ± 0.5 Volts
This calibration compensates for the transfer belt’s condition and the ID sensor
condition, for example, dirt on the surface of the belt or ID sensor.