5.3.2 MEMORY CLEAR/COUNTER CLEAR
The table lists the data that is reset or deleted with SP5-801, SP5-998. The serial
number information, meter charge setting (SP5-930), and meter charge counters
(SP8-58x) are not cleared.
NOTE: In this section (5.3.2), the letter “x” represents a whole number from “0” to
“9”.
Service Program Reset or Deleted
5801 001 All Clear Resets all correction data for process control and all
software counters, and returns all modes and
adjustments to their default values.
5801 002 ENG All Clears the engine settings.
5801 003 SCS SP5-104, 812, 961
SP7-401, 502, 504, 506
SP8-00x, 02x, 03x, 06x, 07x, 42x, 43x, 44x, 451,
46x, 471, 48x, 51x, 52x, 771, 781, 801, 831,
841, 851, 861, 871, 881, 891, 901, 911, 941
5801 004 IMH No SP modes are cleared. All files stored in the
HDD are deleted.
5801 005 MCS No SP modes are cleared.
5801 008 PRT Service settings:
• Bit switches
• Gamma settings (User & Service)
• Toner Limit
User settings:
• Tray Priority
• Menu Protect
• System Setting other than energy saver settings
• I/F Setup (I/O Buffer and I/O Timeout)
• PCL Menu
5801 010 Web Service Clears the netfile application management files and
thumbnails, and initializes the job login ID.
5801 011 NCS All setting of Network Setup (User Menu)
5801 014 Clear DCS Settings Initializes the DCS (Delivery Control Service)
settings.
5801 015 Clear UCS Settings Initializes the UCS (User Information Control
Service) settings.
5801 016 MIRS Setting Initializes the MIRS (Machine Information Report
Service) settings.
5801 017 CCS
Initializes the CCS (
Certification and Charge-
control Service
) settings.
5801 018 SRM Initializes the SRM settings
5801 019 LCS Setting Initializes the LCS settings
5998 001 ENG Setting All engine related SP modes other than the
following:
• Serial number information
• SP modes related to meter charge
• Counters and logging data
5998 002 ENG Counter All counters and logging data related to engine