Service manual

ENGINE SERVICE MODE
G130/G131 5-48 SM
[Jam Alarm]
*CTL [0 to 3 / 3
/ 1/step]
3: 6K, 2: 3K, 1: 1.5K, 0: Disables the jam alarm
5504
Sets the jam alarm level. If a paper jam occurs, the jam alarm counter increases by
+1. If no paper jam occurs while the set number of paper is output, the jam alarm
counter decreases by -1. The jam alarm occurs when the jam alarm counter gets to
+10. This SP is for use with NRS.
[Error Alarm]
*CTL [0 to 255 / G130: 25
, G131: 35 / 1/step]
0: Disables the PM alarm
5505
Sets the error alarm level. If an SC code occurs, the error alarm counter increases
by +1. If no SC code occurs while the set number of paper is output, the jam alarm
counter decreases by -1. The error alarm occurs when the error alarm counter
reaches +5. This SP is for use with NRS.
5507 [Supply Alarm]
Enables or disables the supply alarm.
5507 001 Paper Supply Alarm *CTL
5507 002 Staple Supply Alarm *CTL
5507 003 Toner Supply Alarm *CTL
[0 to 1 / 0
/ 1/step] Alphanumeric
0: OFF, 0: ON
Sets the supply alarm level. A supply alarm counter increases by +1 when a sheet of the related
size is used. The supply alarm occurs when one of the supply alarm counters gets to the set
value. This SP is for use with NRS.
5507 128 Interval: Others *CTL
5507 132 Interval: A3 *CTL
5507 133 Interval: A4 *CTL
5507 134 Interval: A5 *CTL
5507 141 Interval: B4 *CTL
5507 142 Interval: B5 *CTL
5507 160 Interval: DLT *CTL
5507 164 Interval: LG *CTL
5507 166 Interval: LT *CTL
5507 172 Interval: HLT *CTL
[250 to 10000 / 1000
/ 1/step]
[SC Call Setting] 5515
Enables or disables the SC call setting.
5515 001 SC Call Setting *CTL [0 or 1 / 0 / – ]
0: Enable, 1: Disable
This SP is activated only when CSS or NRS is
enabled.