ENGINE SERVICE MODE
SM 5-47 G130/G131
Service Tables
5307 [Summer Time]
Setting *CTL# [ 0 to 1 / NA, EU, ASIA / 1 /step]
0: Disabled
1: Enabled
NA and EUR: 1, ASIA: 0
5307 001
Enables or disables the summer time mode.
NOTE: Make sure that both SP5-307-3 and 4 are correctly set. Otherwise, this SP
is not activated even if this SP is set to "1".
Rule Set (Start) *CTL# 5307 003
Specifies the start setting for the summer time mode.
There are 8 digits in this SP. For months 1 to 9, the "0" cannot be input in the first
digit, so the eight-digit setting for -2 or -3 becomes a seven-digit setting.
1st and 2nd digits: The month. [1 to 12]
3rd digit: The week of the month. [1 to 5]
4th and 5th digits: The day of the week.
[0 to 6 = Sunday to Saturday]
6th digit: The hour. [00 to 23]
7th digit: The length of the advanced time.
[0 to 9 / 1 hour /step]
8th digit: The length of the advanced time.
[0 to 5 / 10 minutes /step]
For example: 3500010 (EU default)
The timer is advanced by 1 hour at am 0:00 on the 5th Sunday in March
• The digits are counted from the left.
• Make sure that SP5-307-1 is set to "1".
Rule Set (End) *CTL# 5307 004
Specifies the end setting for the summer time mode.
There are 8 digits in this SP.
1st and 2nd digits: The month. [1 to 12]
3rd digit: The week of the month. [0 to 5]
4th digit: The day of the week.
[0 to 7 = Sunday to Saturday]
5th and 6th digits: The hour. [00 to 23]
The 7th and 8 digits must be set to "00".
• The digits are counted from the left.
• Make sure that SP5-307-1 is set to "1".
[UCodeCtrClr] Use Code Counter Clear
5404
Clears all counters for users.
[PM Alarm]
*CTL [0 to 9999 / 0
/ 1/step]
0: Disables the PM alarm
5501*
Sets the PM alarm level. A PM alarm is made when this condition occurs: PA x
1000 = PC, where PA is the value set in SP5-501 and PC is the value in the PM
counter. This SP is for use with NRS.