Service manual
ENGINE SERVICE MODE
G130/G131 5-46 SM
SP5-XXX (Mode)
[mm/inch Display]
*CTL 0: mm (Europe/Asia), 1: inch (USA)
5024
Display units (mm or inch) for custom paper sizes.
[Counter Method]
*CTL [0 or 1 / 1 / -]
0: Developments, 1: Prints
5045
Selects the counting method if the meter charge mode is enabled with SP5-930-
001. You can change the setting only one time.
[Toner Refill Displ] Toner Refill Detection Display
5051
Enables or disables the toner refill detection display.
5051 1 Toner Refill Displ *CTL [ 0 or 1 / 0 /- ]
0: enable
1: disable
5055 [Display IP Address]
*CTL 0: NO, 1: Yes
5055 1 Displays the LP’s IP Address on the display panel. (Default = NO)
[Double Count]
*CTL [0 to 2 / 0
/ 1 /step]
0: No, 1: YES, 2: Yes except By-pass
5104
Specifies whether the counter is double clicked for A3/DLT size prints.
[Paper Size]
*BCU
5131
• DOM: Japan
• USA: North America
• ERP: Europe
The default setting changes for each area.
[Bypass Length Setting]
*CTL [0 or 1 / 0
/ -] Alphanumeric
0: OFF, 1: ON
5150
Lets or does not let the by-pass tray feed extra long paper (up to 1260 mm).
[Print By-pass]
*CTL [0 or 1 / 0
/ -]
0: OFF, 1: ON (displays error message)
5179
Enables or disables the alert function for the paper feed misdirection at the by-pass
printing. This function shows an error message when a paper jam occurs because
the paper feed direction is different from the one that has been set with UP mode.
[Set Time]
*CTL# [-1440 to 1440 / 60
/ 1 min./step] Not used
5302
Adjusts the RTC (real time clock) time setting for the local time zone.
Examples: For Japan (+9 GMT), enter 540 (9 hours x 60 min.)
NA :-300 (Montreal)
EU :+ 60 (Paris)
CH :+480 (Beijing)
TW :+480 (Taipei)
AS :+480 (Hong Kong)
⇒
Rev. 10/2005