Service manual
ENGINE SERVICE MODE
G130/G131 5-42 SM
3906
[PC SelfChk] Process Control Self-checks
Non-use Time 1 *BCU [0 to 999 / 0 / 1 sheet /step]
0: Disable
3906 003
Specifies the executing timing of the non-use time process control self-check.
The non-use time process control self-check is automatically done after the number
of prints set with this SP mode has been made and no prints have been made for
the time set with SP3-906-4 since the last print job.
If the conditions are met, the self-check will be done after the print job is completed.
The counter is reset when the initial process control self-checks is done or when a
print is made.
Non-use Time 2 *BCU [0 to 2550 / 480 / 10 minutes/step]
0: Disable
3906 004
Specifies the executing timing of the non-use time process control self-check.
K Coefficient *BCU [0 to 1.00 / 1.00 / 0.01/step] DFU 3906 005
Sets the coefficient to calculate the counter value for black-and-white prints.
With the default setting (100), counters used for process control count up by 1 when
1 black-and-white print has been made.
Pow On Int Time *BCU [0 to 24 / 6 / 1 hour /step]
0: Disable
3906 006
Specifies the executing timing of the initial process control self-check when the
machine recovers from energy saver mode or auto off mode. The initial process
control self-check is cancelled during the time set with this SP.
3910
[Vmin Display] Vmin Display ([Color])
[K] *BCU [0 to 2.00 / 0 / 0.01/step] 3910 001
Displays the current Vmin value for K
[Color] *BCU [0 to 2.00 / 0 / 0.01/step] 3910 002
Displays the lowest current Vmin value for the colors (CMY).
3911
[Vt Display Cur] Vt Current Display ([Color])
3911 001 [K] *BCU
3911 002 [Y] *BCU
3911 003 [M] *BCU
3911 004 [C] *BCU
Displays the current Vt value.
[
0.0 to 5.0 / - / 0.1V/step]
3912
[Vt Display Ave] Vt Average Display ([Color])
3912 001 [K] *BCU
3912 002 [Y] *BCU
3912 003 [M] *BCU
3912 004 [C] *BCU
Displays the average Vt value.
[0.0 to 5.0 / - / 0.1V/step]
3913
[T. Supply Time] Toner Supply Time Display ([Color])
3913 001 [K] *BCU
3913 002 [Y] *BCU
3913 003 [M] *BCU
3913 004 [C] *BCU
Displays the toner supply clutch on time for the
most recent page.
[0 to 5000 / - / 1 ms/step]