Service manual

SC TABLE
G130/G131 4-42 SM
SC No. Item Definition Possible Cause
Related
SCs
Troubleshooting Procedure Type
SC 998 Application
start error
No applications start within 60
seconds after the power is
turned on.
Loose connection of
RAM-DIMM, ROM-
DIMM
Defective controller
Software problem
1. Turn the main switch off and on.
2. Check if the RAM-DIMM and ROM-
DIMM are correctly connected.
3. Reinstall the controller system
firmware.
4. Replace the controller.
CTL
NOTE 1: If a problem always occurs in a specific condition (for example. printer driver setting, image file), the problem may be caused by a software
error. In this case, the following data and information needs to be sent back to your product specialist.
Symptom / Possible Causes / Action taken
Summary sheet (SP mode “Service SP”, SP1-004 [Print
Summary])
SMC - All (SP5-990-001)
SMC - Logging (SP5-990-004)
Printer driver settings used when the problem occurs
All data displayed on the screen (SC code, error code, and program
address where the problem is logged.)
Image file which causes the problem, if possible