Service manual

SC TABLE
G130/G131 4-36 SM
SC No. Item Definition Possible Cause
Related
SCs
Troubleshooting Procedure Type
SC 821 Self-diagnostics error: ASIC [XXXX]: Detailed error code
[0B00] ASIC error The write-&-verify check error
has occurred in the ASIC.
Defective ASIC device
1. Replace the controller. CTL
[0B06] ASIC not
detected
The ASIC is not detected.
Defective ASIC
Poor connection
between North Bridge
and PCI I/F
1. Replace the controller. CTL
[0B10] SHM register
check error
The register test error of the
connection bus occurs.
Data in SHM register is
incorrect.
Defective connection
bus
Abnormal SHM
1. Replace the controller. CTL
SC 822 Self-diagnostic error: HDD (Hard Disk Drive) [XXXX]: Detailed error code
[3003] Timeout error
[3004] Command error
When the main switch is
turned on or starting the self-
diagnostic, the HDD stays
busy for the specified time or
more.
[3013] Timeout error 2
Mandolin does not respond.
The HDD device remains
BUSY for more than 31 s.
The BUSY signal does not
drop within 6 s after the
diagnostic command is
issued to the HDDs.
[3014] Command error
2
Error returned from HDD in
response to the self-
diagnostic command.
Mandolin could not be
located due to a read/write
error at the HDD register.
Loose connection
Defective HDD
Defective controller
device
1. Turn the main switch off and on.
2. Check that the HDD is correctly
connected to the controller.
3. Replace the HDD.
4. Replace the controller.
CTL