Service manual

SC TABLE
G130/G131 4-18 SM
SC No. Item Definition Possible Cause
Related
SCs
Troubleshooting Procedure Type
SC
460-
002
Thermistor 1
error (short
circuit)
When the temperature
detected by the thermistor 1,
which is at the left (fusing unit)
side of the laser optics unit, is
higher than 70°C for 10
seconds consecutively, the
BCU determines that the circuit
is shorted and shows this SC
code.
Thermistor 1 defective
Cable connection error
BCU defect
1. Check the cable connections.
2. Replace the thermistor.
3. Replace the BCU.
C
SC
461-
001
Thermistor 2
error (open
circuit)
When the temperature
detected by the thermistor 2,
which is at the right (paper feed
section) side of the laser optics
unit, is less than -30°C for 10
seconds consecutively, the
BCU determines that the circuit
is open and shows this SC
code.
Thermistor 2 defective
Cable connection error
BCU defect
1. Check the cable connections.
2. Replace the thermistor.
4. Replace the BCU.
C
SC
461-
002
Thermistor 2
error (short
circuit)
When the temperature
detected by the thermistor 2,
which is at the right (paper feed
section) side of the laser optics
unit, is higher than 70°C for 10
seconds consecutively, the
BCU determines that the circuit
is shorted and shows this SC
code
Thermistor 2 defective
Cable connection error
BCU defect
1. Check the cable connections.
2. Replace the thermistor.
3. Replace the BCU.
C