SC TABLE
G130/G131 4-14 SM
SC No. Item Definition Possible Cause
Related
SCs
Troubleshooting Procedure Type
SC 240 LD over
240-001: Y
240-002: M
240-003: C
240-004: K
The power supply for the LD
unit exceeds 110 mA.
LD worn out
(current/light output
characteristics have
changed.)
LD broken (short
circuit)
1. Replace the laser optics-housing
unit.
C
SC 285 Line position
adjustment
(MUSIC) error
Line position adjustment fails
four consecutive times.
Pattern sampling error
due to insufficient
image density of
patterns used for the
adjustment
Inconsistency in the
sampling line position
adjustment pattern due
to dust on the pattern,
damage to the OPC
drum, damage or toner
dropped on the
transfer belt, or a dirty
or defective ID sensor
1. Check and fix the problem that
causes low image density. .
2. Clean or replace the transfer belt
and/or the ID sensor.
3. Replace the PCU or clean the
development unit that causes toner
to drop on the transfer belt.
C
SC 370 TD sensor [K]:
Adjustment
error
SC 371 TD sensor [Y]:
Adjustment
error
SC 372 TD sensor [C]:
Adjustment
error
SC 373 TD sensor [M] :
Adjustment
error
During the developer
initialization, the output value of
the TD sensor is out of the
adjustment range (X ± 0.2V).
NOTE: “X” is adjusted with
SP3-006-005 to -008.
Poor connection (TD
sensor outputs is less
than 0.5V.)
Defective TD sensor
1. Turn the main switch off and on.
2. Reset the related color development
unit.
3. Replace the related color
development unit.
D