Service manual

SC TABLE
G130/G131 4-10 SM
4.3 SC TABLE
SC No. Item Definition Possible Cause
Related
SCs
Troubleshooting Procedure Type
SC 195 Serial Number
Mismatch
Serial number stored in the
memory does not have the
correct code.
NVRAM defective
BCU replaced without
original NVRAM
Incorrect DIP-switch
setting
Open the front cover and turn on the
main switch. Check the serial number
with SP5-811-002.
If the stored serial number is incorrect,
contact your supervisor.
For DIP-switch settings, see section
5.8.
D
SC 201 Polygon motor
error
The polygon mirror motor
does not reach the targeted
operating speed within 10
seconds after turning on.
The lock signal does not
become high within 3
seconds after turning off the
polygon motor.
The lock signal become high
0.2 second or more while
the polygon motor reaches
the targeted operating
speed.
Polygon mirror motor
error
Abnormal GAVD
behavior
Cable disconnection
SC 221-
1 to 4
1. Turn the main switch off and on.
2. Check the cables.
3. Replace the polygon motor.
D