INSTALLATION AND OPERATING MANUAL Series NKL, NKLP, NKS, NKSP, NK, NKP Richter Shut-off and Control Butterfly Valve Lug-style body: Series NKL Sandwich-type body: Series NKS Double-flange body: Series NK Keep for future use! This operating manual must be strictly observed before transport, installation, operation and maintenance Subject to change without notice. Reproduction is generally permitted with indication of the source.
Series NKL, NKLP, NKS, NKSP, NK, NKP Page 2 List of Contents List of Contents 2 Relevant documents 2 1 Technical data 3 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 Type code.................................................... 3 Name plate, CE and body markings ........... 4 Tightening torques....................................... 5 Dimensions.................................................. 6 Flow rate value kv [m³/h] ............................ 6 Weights (ca. kg) .......................................
Series NKL, NKLP, NKS, NKSP, NK, NKP 1 Page 3 Technical data Manufacturer: Richter Chemie-Technik GmbH Otto-Schott-Str. 2 D-47906 Kempen Telephone: +49 (0) 2152 146-0 Fax: +49 (0) 2152 146-190 richter-info@richter-ct.com E-Mail: Internet: http://www.richter-ct.com Designation: Shut-off and control butterfly valve 3 body designs: lug-style, sandwich-type and double flange.
Series NKL, NKLP, NKS, NKSP, NK, NKP Page 4 Shut-off and control butterfly valve with sandwich-type body NKS/F Disc/stem unit of PFA, with lockable hand lever or worm gear with manual actuation NKSP/F Disc/stem unit of PFA, with actuator NKS/F-S Disc/stem unit of stainless steel, with lockable hand lever or worm gear with manual actuation NKSP/F-S Disc/stem unit of stainless steel, with actuator NKS/F-H Disc/stem unit of Hastelloy C4, with lockable hand lever or worm gear with manual actuation NKSP/F-H D
Series NKL, NKLP, NKS, NKSP, NK, NKP 1.3 Tightening torques All screws greased, tighten in diametrically opposite sequence! After the plant has been started up (especially with the first temperature load) the tightening torques must be checked and the correct value set again. The tightening torques for pipe screws and body screws mentioned must not be exceeded. For an exception, see Section 8, flange connection valve/pipe is leaking.
Series NKL, NKLP, NKS, NKSP, NK, NKP 1.4 Page 6 Dimensions 1 Nom. size[ 1 E T [mm] [mm] [inch] [mm] 50 80 100 150 200 250 300 350 400 2“ 3“ 4“ 6“ 8“ 10“ 12“ 14“ 16“ 28 67 87 142 193 243 292 343 389 L 2 Connection 3 [mm] 4 17,5 24,5 48 71 92 112 137 150 43 46 52 56 60 68 78 78 102 1 See also Section 6.
400 16“ 97,0 69,0 -- -- 15,0 Actuator see data of the manufacturer 1.7 Pressure-temperature-diagram 1.8 When used in the area of application of ASME, the low temperature of ASTM A395 is limited to – 20 °F (– 29 °C). Breakaway torques Nom. size A special material is used for the disc/stem unit for operating limits under °+ 14° F to – 76 °F (– 10 °C to – 60 °C). When used in the minus temperature range, the regulations applicable in the country in question must be observed.
Series NKL, NKLP, NKS, NKSP, NK, NKP 2 Page 8 Notes of safety This operating manual contains fundamental information which is to be observed during installation, operation and maintenance. It must therefore be read before installation and commissioning! For valves which are used in potentially explosive areas, see Section 3. Installation and operation are to be performed by qualified staff. The area of responsibility, authority and supervision of the staff must be regulated by the customer.
Series NKL, NKLP, NKS, NKSP, NK, NKP 3 Page 9 Safety notes for applications in potentially explosive areas based on the Directive 94/9/ EC (Atex 95) The valves are intended for use in a potentially explosive area and are therefore subject to the conformity assessment procedure of the directive 94/9/EC (ATEX).
Series NKL, NKLP, NKS, NKSP, NK, NKP 4 Safety note for valves, certified to Clean Air Act (TA-Luft) On request, this valve can be supplied compliant with the German Clean Air Code. Certificate / Manufacturer Declaration Validity is dependent on the operating instructions being read and observed. 5 Storage If the valve is not installed immediately after delivery, it must be put into proper storage.
Series NKL, NKLP, NKS, NKSP, NK, NKP 5.5 Disposal Parts of the valve may be contaminated with medium which is detrimental to health and the environment and therefore cleaning is not sufficient. Risk of personal injury or damage to the environment due to the medium! Wear protective clothing when work is performed on the valve. 6 Page 11 Prior to the disposal of the valve: Collect any medium, etc. which has escaped and dispose of it in accordance with the local regulations.
Series NKL, NKLP, NKS, NKSP, NK, NKP 6.4.1 Additional advice for shut-off and control butterfly valve with actuator For single-acting actuators a locking plate has been fitted into the bracket, blocking the stem at a disc opening of 10 – 15°. Remove the locking plate before the first test actuation, screw in again hex. screw 901/1. Slightly actuate the actuator. Please pay attention to the drawing in Section 5.4. 7 Operation 7.
Series NKL, NKLP, NKS, NKSP, NK, NKP 8 Malfunctions Flange connection ball valve/pipe is leaking Retighten the flange screws to a tightening torque according to Section 1.3. If this does not remedy the leak, the recommended torques may be exceeded by 10%. If this also fails to stop the leak, dismantle and inspect the ball valve. Dismount and inspect the valve. Stem passage leaking With no safety stuffing box: Dismount valve and repair.
Series NKL, NKLP, NKS, NKSP, NK, NKP Page 14 9.1.1 Safety stuffing box 9.2.3 Remotely actuated Insert sealing foil 413 between the upper and lower halve of the shell 120. Displace packing rings 402/1 by 90° against each other Screw in stuffing box screws 901/3. Only tighten in the event of a leak. Safety stuffing box with monitor using warning connection Tighten stuffing box bolts 901/3 with torque in accordance with Section 1.3. See also Section 9.1.3.
Series NKL, NKLP, NKS, NKSP, NK, NKP 9.3.3 Proximity switch The proximity switch reliably indicates the closed position of the valve disc. The signal penetrates the thickwalled lining. 9.4 Tests Following tests would be done after the assembly. Measurement of the breakaway torque The breakaway torque required for opening and closing the valve is to be ascertained. The maximum torque should not exceed the values given in Section 1.8.
Series NKL, NKLP, NKS, NKSP, NK, NKP 10.
Series NKL, NKLP, NKS, NKSP, NK, NKP 10.
Series NKL, NKLP, NKS, NKSP, NK, NKP 10.
Series NKL, NKLP, NKS, NKSP, NK, NKP 10.6 Connecting dimensions worm gear all dimensions in mm 10.
Series NKL, NKLP, NKS, NKSP, NK, NKP Page 20 10.
Series NKL, NKLP, NKS, NKSP, NK, NKP Page 21 10.
Series NKL, NKLP, NKS, NKSP, NK, NKP Page 22 10.
A Unit of IDEX Corporation Konformitätserklärung nach Richtlinie 97/23/EG für Richter Chemie-Technik GmbH Armaturen Declaration of conformity according the directive 97/23/EG for Richter Chemie-Technik GmbH valves Hiermit erklärt die Richter Chemie-Technik GmbH die Konformität der gelieferten Armaturen gemäß der Richtlinie 97/23/EG (Druckgeräterichtlinie). Herewith Richter Chemie-Technik GmbH declares the conformity of the delivered valves according to the directive 97/23/EG (Pressure Equipment Directive).
Safety Information / Declaration of No Objection Concerning the Contamination of Richter-Pumps, -Valves and Components 1 SCOPE AND PURPOSE Each entrepreneur (operator) carries the responsibility for the health and safety of his employees. This extends also to the personnel, who implements repairs with the operator or with the contractor. Enclosed declaration is for the information of the contractor concerning the possible contamination of the pumps, valves and component sent in for repair.
Declaration about the Contamination of Richter Pumps, -Valves and Components The repair and/or maintenance of pumps, valves and components can only be implemented if a completely filled out declaration is available. If this is not the case, delay of the work will occur. If this declaration is not attached to the devices, which have to be repaired, the transmission can be rejected. Every aggregate has to have it’s own declaration.
FAX Fax No. () Pages (incl. cover sheet) () To: () Contact person: () Your order No.: Our Kom. No.: Reference: () () () Extension: - () E-Mail Address: () Date: () Serial No.: () Dear Sirs, The compliance with laws for the industrial safety obligates all commercial enterprises to protect their employees and/or humans and environment against harmful effects while handling dangerous materials.